首页 新闻中心 生物通商城 新技术专栏 技术讲座 BBS交流 人才市场 核心刊物 会展中心 技术与投资
·关于我们
·联系方式
·刊登广告
您的位置: 首页 >> >> >> 正文

第一个自动DNA测序预染胶:CastAway Precast Gels
关键字:快速|自动DNA测序|CastAway Precast Gels    www.ebiotrade.com  时间:2005年11月3日17:11    来源:Stratagene

(http://www.ebiotrade.com/)

LI-COR and Stratagene release the first commercially available precast gels for automated DNA sequencing and genetic analysis. Stratagene抯 CastAway ?/SUP> gels* for the LI-COR system are provided polymerized and are ready to load in less than 30 minutes. Use the CastAway gels with LI-COR抯 IR2 Automated DNA Analysis System to obtain more than 16,000 bases of sequence data or to analyze 1,440 genotypes per gel.

DNA sequence analysis remains an essential technology for elucidating gene structure and function. For more than a decade, automated methods have been developed to improve the throughput and accuracy of DNA sequencing and genotyping.1,2,3,4 In general, the technology involves the real-time detection of fluorescently labeled DNA fragments as they move through a portion of an electrophoresis gel that is irradiated by a laser. The fluorescence emission is collected by a detector located at a fixed distance from the loading wells. The resultant signal produces a band pattern, which correlates to a DNA sequence or to a specific DNA fragment size for genotyping applications.

One limitation of automated DNA sequencers is the time required to cast gels used to separate DNA fragments electrophoretically. Hence, LI-COR and Stratagene adapted the CastAway precast sequencing gels5 for use on the Model 4200 (IR2) Automated DNA Analysis System.6,7 By using precast gels on an infrared fluorescence automated DNA sequencer, convenience and throughput in DNA sequence analysis are improved.

Precast Gels

li-cor#1

Figure 1

Pouring a slab gel the conventional way can take more than 2 hours: assemble the gel apparatus, mix reagents, degas the gel solution, pour the gel, and complete gel polymerization. In contrast, Stratagene抯 CastAway gels are provided polymerized and ready to load in less than 30 minutes (Figure 1).

The gel apparatus and precast gel are easily assembled in four steps (Figure 1). First, remove the CastAway gel from its packaging and allow it to equilibrate to room temperature. Second, rinse the front and back glass plates with distilled water and dry with lint-free wipes. Third, tighten the left and right precast gel rails and the upper buffer tank into position, and the gel assembly is complete. Finally, install the gel apparatus on the LI-COR instrument and carry out a 20 minute pre-electrophoresis prior to loading the gel.

Focusing and Electrophoresis

The LI-COR IR2 Automated DNA Analyzer uses a scanning infrared fluorescence microscope to detect the electrophoretic movement of fluorescently labeled DNA molecules in real time. The system is a two-dye infrared automated DNA sequencer that can detect the products of two sequencing reactions in parallel by generating two separate gel images, each corresponding to the fluorescence emission of a different infrared dye (700 nm channel for IRD 700; 800 nm channel for IRD 800).

The microscope consists of one or two laser diodes for providing dye excitation (wavelength at 685 nm and 785 nm) and one or two avalanche photodiodes for detecting the fluorescence emission.6,7 By using infrared radiation, the background fluorescence caused by the soda lime glass of the precast gel is greatly reduced. Moreover, variations in precast gel thickness can be accommodated by autofocusing the fluorescence microscope to assure optimal signal-to-noise ratios for a given gel configuration (Figure 2).

li-cor#2

Figure 2

DNA reaction products are heat denatured and loaded on the CastAway gel using a 48- or 64-well sharktooth comb. To separate DNA fragments produced in a sequencing reaction, electrophoresis is carried out at a constant 25 W (ca. 50 V/cm and 18 to 22 mA) (Figure 3). To obtain banding patterns of short tandem repeat polymorphisms (STRPs), fluorescently labeled PCR products are separated using electric field conditions of 1000 V, 45 mA, and 45 W (Figure 4). During electrophoresis, the precast gel is maintained at 45篊 by a thermostatically controlled heater plate that is in contact with the rear glass plate. After electrophoresis, precast gels are discarded, thus eliminating the need to clean glass plates.

li-cor#3

Figure 3

DNA Sequencing and Genotyping Applications

The Model 4200 (IR2) Automated DNA Analysis System was used in conjunction with the CastAway precast gel to obtain sequence from M13mp19 single-stranded DNA using the M13 (-29) forward primer (Figure 3). The autosequencer called 600 bases with 99.7% accuracy, and data were collected in 2.5 hours (from time of load) using the aforementioned electrophoresis conditions. Read lengths greater than 500 bases are typically achieved for sequence ladders generated on precast gels and analyzed in either the system抯 700- or 800-nm channel; this compares to read lengths obtained with manually poured gels (data not shown). The total base number per precast gel is greater than 16,000 when the gel is maximally loaded (i.e., 32 sequencing samples).

li-cor#4

For genetic analysis, STRP banding patterns were obtained using a precast gel on the automated infrared DNA analyzer. In Figure 4, four STRP loci are detected in each lane (four multiplexed reactions per channel). Expect 1,440 genotypes (60 lanes x 4 loci x 2 channels x 3 loads) for a typical throughput per precast gel, which is equivalent to manually poured gels. Additionally, the precast gel can be reloaded three times (Figure 4), making fluorescence STRP analysis cost effective as well.

Figure 4

Conclusions

Use Stratagene抯 CastAway gels for the LI-COR system on the IR2 DNA Analysis System for automated DNA sequencing and genotyping applications. CastAway precast gels are made with soda-lime float glass plates, which produce minimal background fluorescence with the system抯 infrared technology. Therefore, it is unlikely these precast gels could be used with visible fluorescence automated DNA sequencers, such as the ABI PRISM?/SUP> 377, since the system sensitivity would be lower due to significant emission of background fluorescence by the soda-lime plates. Further, CastAway gels compare favorably to the standard LI-COR manually poured 25-cm gel梬ith respect to electrophoresis run time, band morphology, band resolution, and signal strength梐nd both gel types produce a similar sequence read length and accuracy.


  相关文章/今日要闻:
·MJ Research &... (11-3)
·自动... (11-3)
·Premier Biosoft’... (11-3)
·染色质免疫沉淀protocol (11-3)
·Review:荧光蛋白在癌细胞研... (11-3)
·罗氏提供快100倍、低价的测序系统 (11-3)
·GenomiPhi™... (11-3)
·Erase-a-base系统 (11-3)
·PCR 酶应用一览 (11-3)
·MJ Research 长片段测... (11-3)
·新技术:测序如何加快100倍的 (11-3)
·美科学家发明DNA染色测序法 (11-3)
·科学家开发出更快的测序技术 (11-3)
·酶联免疫吸附实验(ELISA)【3】 (11-1)
读后感言: 用户名 密码

 查看评论
  请注意:
· 文如其人,请对自己的言行负责。
· 发言请遵守:爱国守法,文明自律
· 生物通保留处理留言的一切权利

生物通版权与免责声明:

 
凡注明"生物通"的所有文字稿件均为生物通编译自国外生物医学类权威期刊或媒体,中文版权均属生物通所有,任何媒体、网站或个人未经本网协议授权不得转载、链接、转贴或以其他方式复制发表。已经本网协议授权的媒体、网站,在转载使用时必须注明"稿件来源:生物通",违者本网将依法追究责任。
即日起生物通转载自其他媒体的转载稿均在文章开头或者结尾注明出处,本网转载出于传递信息共享之目的,不作商业用途,不承担相关责任,也不意味着赞同其观点或证实其内容的真实性。如其他媒体、网站或个人引用必须注明真正的"稿件来源",并自负版权等法律责任,生物通不承担相应的后果。否则本网将依法追究责任。如对稿件内容有疑议,请及时与我们联系info@ebiotrade.com
如转载稿涉及版权等问题,请作者立即通知生物通撤销相应文章。
新 闻 检 索
-热点招聘-

生物通简介 | 广告服务 | 招聘信息 | 帮助信息 | 会员注册 | 意见反馈 | 联系我们
版权所有 生物通
Copyright© 2000-2003 eBiotrade.com, All Rights Reserved
联系信箱:info@ebiotrade.com
经营许可证编号:京ICP证010510